Methylcobalamin 5,000 mcg/ml, Sodium Chloride 0.9%,1 mL SDV, Vital Care Compounder, Hattiesburg, MS
| Class II |
Lot#: 389279, Use by 09-09-16
|
Lack of Assurance of Sterility: Aluminum crimps do not fully seal the rubber stopper to the vials.
| Vital Care Compounder 115 S 40th Ave Hattiesburg, MS 39402-6600 | |
Brilliant Blue G BBG, 0.025%, Sterile Injection, 0.5 mL Single Dose Vial, Vital Care Compounder, Hattiesburg, MS
| Class II |
Lot#: 395575, Use by 07-27-2016
|
Lack of Assurance of Sterility: Aluminum crimps do not fully seal the rubber stopper to the vials.
| Vital Care Compounder 115 S 40th Ave Hattiesburg, MS 39402-6600 | |
Trypan Blue 0.3%, 0.5 mL Vial, Vital Care Compounder, Hattiesburg, MS
| Class II |
Lot#: 391462, Use by 10-06-2016
|
Lack of Assurance of Sterility: Aluminum crimps do not fully seal the rubber stopper to the vials.
| Vital Care Compounder 115 S 40th Ave Hattiesburg, MS 39402-6600 quoted from FDA July 6, 2016 Enforcement Report |
Human Medications, Human Drugs, Animal Medications, Animal Drugs, Pharmacy law, Pharmaceutical law, Compounding law, Sterile and Non Sterile Compounding 797 Compliance, Veterinary law, Veterinary Compounding Law; Health Care; Awareness of all Types of Compounding Issues; Pharmacy Benefit Managers (PBMs), Outsourcing Facilities Food and Drug Administration and Compliance Issues